The Bloc device has brought new hope to individuals struggling with obesity by offering an alternative to traditional weight-loss surgery. This FDA-approved, implantable device works by blocking hunger signals between the stomach and brain through gentle electrical pulses. However, like all electronic devices, it may sometimes run into technical issues—one of the most common being: “My Bloc device won’t charge.”
If you’re facing this issue, you’re not alone. While it’s frustrating to deal with any device malfunction, especially one related to your health, the good news is that many charging issues can be resolved with a bit of guidance and patience. In this article, we’ll explore why your Bloc device might not be charging, how to troubleshoot the problem, and what steps you should take to ensure your therapy continues without interruption.
Understanding How the Bloc System Works
Before diving into the charging issue, it helps to briefly understand the components of the Bloc system:
- Implanted Neuroregulator – This is the core of the device, surgically placed near the vagus nerve.
- External Transmit Coil – Worn over the skin, it wirelessly transmits energy to the implanted device.
- Mobile Charger & Controller – These let you monitor the device and ensure it receives regular charging.
- Charging Belt – This holds the external coil in place and connects it to the mobile charger.
All of these parts need to work together for the system to function properly. If any one component isn’t working, the charging process may fail.
Common Reasons Your Bloc Device Won’t Charge
There are several reasons why your Bloc device might not be charging. Identifying the root cause is the first step in resolving the issue.
1. Improper Coil Placement
The most common cause of charging failure is that the external coil isn’t aligned properly with the implanted device. If it’s off even slightly, the device may not receive a charge.
2. Faulty Charging Cable or Power Adapter
If the cable connecting your charging coil to the charger is damaged or the power adapter is faulty, the device won’t receive power. Wear and tear or loose connections can be the culprit.
3. Dead Battery in External Charger
If your external charger hasn’t been charged itself, it may be incapable of delivering energy to the coil, and in turn, your implanted device.
4. Software Glitch
Sometimes the controller software may freeze or crash, preventing proper monitoring or charging. A simple restart may fix this.
5. Damaged or Worn-Out Components
Like any electronic device, Bloc components can degrade over time. Frequent use, exposure to moisture, or accidental damage can impact their functionality.
Step-by-Step Troubleshooting Guide
Here’s a practical checklist you can follow if your Bloc device won’t charge:
Step 1: Check Coil Placement
- Ensure the coil is centered directly over the implanted device (typically just below the rib cage).
- Use a mirror or ask someone to help with proper alignment.
- Make sure the belt is snug enough to hold the coil in place without shifting.
Step 2: Inspect All Connections
- Examine the power cord and adapter for any visible damage.
- Make sure everything is securely plugged in.
- Try using a different wall outlet or charging adapter if available.
Step 3: Charge the External Controller
- If your controller is showing no lights or response, it may need to be charged itself before it can charge the implant.
Step 4: Reboot the System
- Turn the controller off and on again.
- Sometimes a reboot will refresh the software and allow the device to recognize the charging coil.
Step 5: Clean the Contacts
- Use a dry, clean cloth to gently wipe any dust or residue from the coil, charger, or controller.
- Never use water or liquid cleaners.
When to Contact Support or Your Doctor
If you’ve tried all the steps above and the Bloc device still won’t charge, it may be time to seek professional assistance.
- Contact the Manufacturer’s Customer Support: They can help troubleshoot over the phone or via email. Be ready to provide the serial number of your device and a description of the issue.
- Speak to Your Bariatric Surgeon or Clinic: They can check whether the implant itself is working and if a replacement part is needed.
- Don’t Attempt DIY Repairs: Opening the controller or tampering with parts can void your warranty and may lead to further issues.
Preventing Charging Issues in the Future
Here are a few tips to minimize future problems:
- Charge regularly as recommended by your healthcare provider.
- Store the device and accessories in a dry, clean place.
- Avoid pulling or bending cords, which can lead to breakage.
- Inspect equipment weekly to catch issues before they become serious.
Conclusion: Stay Calm and Act Promptly
Having your Bloc device fail to charge can be stressful, especially when it’s essential for managing your health and weight loss journey. But most issues are fixable with basic troubleshooting. Remember to stay calm, follow the steps carefully, and seek professional help if needed. With the right support and care, you’ll have your device back up and running in no time.
Technology is a powerful tool in healthcare, but it requires occasional maintenance and patience. Being proactive and informed ensures that your journey with Bloc Therapy remains on track—helping you take control of your health, one day at a time.